SmartRack Enclosures

SmartPro RM

SmartPro Rackmount UPS Systems

Intelligent, line interactive UPSs for hubs, routers and network servers

SmartPro Rackmount UPS Systems provide intelligent, microprocessor controlled protection for network servers in a 19" rackmount configuration. These UPS systems are designed to provide maximum performance under heavy loads, ensuring your systems will remain up and running through power outages.

  • Compact design (as slim as 3U high) allows you to better utilize rack space
  • FREE PowerAlert Software and complete cabling manage and upgrade every network UPS system
  • Multi-level automatic voltage regulation keeps servers working through low voltage (brownouts) and high voltage conditions without using battery power
  • Reliable battery power keeps networks running through blackouts
  • RFI/EMI line noise filtering prevents interference (i.e. from motors, lights and radio transmissions) from affecting your computer
  • NEW! All models feature:
    • Hot-swappable battery replacement for 100% uptime
    • Select models include up to three serial ports for multiple server control and expandable battery capability for extended runtimes

Optional Battery Packs:

  • BP-24V33 (Extends runtimes of SmartPro 2200 RM XL and 3000 RM)
  • BPRM (Adapter to support BP-24V33)
New! SmartPro 450 RT Flyer
(PDF format - 196KB)

Model NEW!
Smart 450 RT
SmartPro 700 RM SmartPro 1050 RM SmartPro 1400 RM SmartPro 2200 RM SmartPro 2200 RM XL SmartPro 3000 RM
Input/Output Voltage 120 120 120 120 120 120 120
Input/Output Hz 60 60 60 60 60 60 60
Output VA 450 700 1050 1400 2200 2200 3000
Output Watts 280 450 705 940 1700 1700 2400
UPS Type Line Interactive Line Interactive Line Interactive Line Interactive Line Interactive Line Interactive Line Interactive
Online Waveform Pure Sine Pure Sine Pure Sine Pure Sine Pure Sine Pure Sine Pure Sine
On Battery Waveform PWM Sinusoidal PWM Sinusoidal PWM Sinusoidal PWM Sinusoidal PWM Sinusoidal PWM Sinusoidal PWM Sinusoidal
Voltage Regulation Automatic voltage correction back to nominal levels, boosting 87-110 volt input and reducing 125-140 volt input. Automatic voltage correction back to nominal levels, boosting 87-110 volt input and reducing 125-140 volt input. Automatic voltage correction back to nominal levels, boosting 87-110 volt input and reducing 125-140 volt input. Automatic voltage correction back to nominal levels, boosting 87-110 volt input and reducing 125-140 volt input. Automatic voltage correction back to nominal levels, boosting 87-110 volt input and reducing 125-140 volt input. Automatic voltage correction back to nominal levels, boosting 87-110 volt input and reducing 125-140 volt input. Automatic voltage correction back to nominal levels, boosting 87-110 volt input and reducing 125-140 volt input.
Full Load Runtime (min.) Call 12 8 10 13 13+ 7+
1/2 Load Runtime (min.) Call 28 23 26 29 29+ 23+
Typical Runtime (min.) Call up to 52 min. up to 68 min. up to 78 min. up to 4 hours up to 8 hours up to 8 hours
Recharge Rate (hours) Call 2-4 2-4 2-4 2-4 2-4 2-4
Transfer time (ms.) Call 2-4 2-4 2-4 4-6 4-6 4-6
Joules Call 480 480 480 480 480 480
Maximum Surge Current (amps) Call 36,000 36,000 36,000 36,000 36,000 36,000
Suppression Response Time Call Call 0 ns. (instantaneous) 0 ns. (instantaneous) 0 ns. (instantaneous) 0 ns. (instantaneous) 0 ns. (instantaneous)
EMI/RFI Noise Reduction Greater than 55 dB @ 1 MHz Greater than 55 dB @ 1 MHz Greater than 55 dB @ 1 MHz Greater than 80 dB @ 1 MHz Greater than 80 dB @ 1 MHz Greater than 80 dB @ 1 MHz Greater than 80 dB @ 1 MHz
High Volt Switch to Battery 140 140 140 140 140 140 140
Low Volt Switch to Battery 87 87 87 87 87 87 87
Outlet Type (f) Call 8 NEMA 5-15R 8 NEMA 5-15R 8 NEMA 5-15R 8 NEMA 5-15R 6 NEMA 5-15R + 2 NEMA 5-20R 6 NEMA 5-15R + 2 NEMA 5-20R
Cord Length Call 12 ft. 12 ft. 12 ft. 12 ft. 12 ft. 12 ft.
Plug Type (m) NEMA 5-15P NEMA 5-15P NEMA 5-15P NEMA 5-15P NEMA 5-15P NEMA 5-20P NEMA L5-30P
Dimensions HxWxD (inches) Call 5.25 x 15.75 x 10.5 Fits standard 19 inch rack. Uses 3 rack spaces. 5.25 x 15.75 x 10.5 Fits standard 19 inch rack. Uses 3 rack spaces. 5.25 x 15.75 x 10.5 Fits standard 19 inch rack. Uses 3 rack spaces. 7 x 14.75 x 17.75 Fits standard 19 inch rack. Uses 4 rack spaces. 7 x 14.75 x 17.75 Fits standard 19 inch rack. Uses 4 rack spaces. 7 x 14.75 x 17.75 Fits standard 19 inch rack. Uses 4 rack spaces.
Shipping Weight (lb.) Call 32 38 43 96 104 105
Fax/Modem Surge Protection Not included. Order add-on module #DTEL2 Not included. Order add-on module #DTEL2 Not included. Order add-on module #DTEL2 Not included. Order add-on module #DTEL2 Not included. Order add-on module #DTEL2 Not included. Order add-on module #DTEL2 Not included. Order add-on module #DTEL2
Network Interface Port 2 Built-in DB9 SMART communications ports for use with bundled PowerAlert Plus software and cabling 2 Built-in DB9 SMART communications ports for use with bundled PowerAlert Plus software and cabling 2 Built-in DB9 SMART communications ports for use with bundled PowerAlert Plus software and cabling 2 Built-in DB9 SMART communications ports for use with bundled PowerAlert Plus software and cabling 3 Built-in DB9 SMART communications ports for use with bundled PowerAlert software and cabling. 3 Built-in DB9 SMART communications ports for use with bundled PowerAlert software and cabling. 3 Built-in DB9 SMART communications ports for use with bundled PowerAlert software and cabling.
Software and Cable Included Includes PowerAlert Plus Software and 2 monitoring cables Includes PowerAlert Plus Software and 2 monitoring cables Includes PowerAlert Plus Software and 2 monitoring cables Includes PowerAlert Plus Software and 2 monitoring cables Includes PowerAlert Plus Software and 3 monitoring cables Includes PowerAlert Plus Software and 3 monitoring cables Includes PowerAlert Plus Software and 3 monitoring cables
Product Warranty (yr.) 2 2 2 2 2 2 2
Ultimate Lifetime Insurance $50,000 $50,000 $50,000 $50,000 $50,000 $50,000 $50,000
Battery Access Access door allows user replaceable, hot swappable access of UPS batteries Access door allows user replaceable, hot swappable access of UPS batteries Access door allows user replaceable, hot swappable access of UPS batteries Access door allows user replaceable, hot swappable access of UPS batteries Access door allows user replaceable, hot swappable access of UPS batteries Access door allows user replaceable, hot swappable access of UPS batteries Access door allows user replaceable, hot swappable access of UPS batteries
Controls, Indicators, and Additional Features Includes system on/off and battery test switches, and LEDs to indicate 17 status levels, such as on-line/on-battery operational status, voltage input correction activity, battery and battery charger status, load level, and audible alarms. Includes system on/off and battery test switches, and LEDs to indicate 17 status levels, such as on-line/on-battery operational status, voltage input correction activity, battery and battery charger status, load level, and audible alarms. Includes system on/off and battery test switches, and LEDs to indicate 17 status levels, such as on-line/on-battery operational status, voltage input correction activity, battery and battery charger status, load level, and audible alarms. Includes system on/off and battery test switches, and LEDs to indicate 17 status levels, such as on-line/on-battery operational status, voltage input correction activity, battery and battery charger status, load level, and audible alarms. Includes system on/off and battery test switches, and LEDs to indicate 17 status levels, such as on-line/on-battery operational status, voltage input correction activity, battery and battery charger status, load level, and audible alarms. Includes system on/off and battery test switches, and LEDs to indicate 17 status levels, such as on-line/on-battery operational status, voltage input correction activity, battery and battery charger status, load level, and audible alarms. Includes system on/off and battery test switches, and LEDs to indicate 17 status levels, such as on-line/on-battery operational status, voltage input correction activity, battery and battery charger status, load level, and audible alarms.

Back To Top
2004 Sentinel Power Inc.. All rights reserved.
Last Updated 03/18/10