Home | Company Info | Products | Articles | Contact Us | Search Our Site | Site Map
OmniPro Series

OmniSmart

OmniSmart PNP UPS Systems

Line interactive power protection for PCs, workstations and servers

OmniSmart UPS Systems combine automatic voltage correction with long-lasting battery backup power to keep you working brownouts and blackouts.

  • Multi-level automatic voltage regulation keeps equipment working through low voltage (brownouts) and high voltage conditions without using battery power
  • Serial port and FREE PowerAlert software are included to provide automatic unattended shutdown
  • Reliable battery power keeps your equipment running safely through blackouts
  • RFI/EMI line noise filtering prevents interference (i.e. from motors, lights and radio transmissions) from affecting your computer
  • NEW! Select models feature:
    • 6 outlets (3 UPS and surge protected, 3 surge-only protected) to safeguard your computer and all peripherals
    • 2-line modem/fax protection to stop surges on two phone lines simultaneously
    • Convenient battery replacement door
 

Model OmniSmart 300 PNP OmniSmart 450 PNP OmniSmart 675 PNP OmniSmart 850 PNP OmniSmart 1050 PNP OmniSmart 1400 PNP
Input/Output Voltage 120 120 120 120 120 120
Input/Output Hz 60 60 60 60 60 60
Output VA 300 450 675 850 1050 1400
Output Watts 180 300 425 570 705 940
UPS Type Line Interactive Line Interactive Line Interactive Line Interactive Line Interactive Line Interactive
Online Waveform Pure Sine Pure Sine Pure Sine Pure Sine Pure Sine Pure Sine
On Battery Waveform PWM Sinusoidal PWM Sinusoidal PWM Sinusoidal PWM Sinusoidal PWM Sinusoidal PWM Sinusoidal
Voltage Regulation Line interactive system corrects voltage to nominal levels, boosting input between 92 to 105 volts and reducing input between 134 and 150 volts. Output voltage in battery mode is regulated to 120 volts +/- 5%. Line interactive system corrects voltage to nominal levels, boosting input between 92 to 105 volts and reducing input between 134 and 150 volts. Output voltage in battery mode is regulated to 120 volts +/- 5%. Line interactive system corrects voltage to nominal levels, boosting input between 92 to 105 volts and reducing input between 134 and 150 volts. Output voltage in battery mode is regulated to 120 volts +/- 5%. Line interactive system corrects voltage to nominal levels, boosting input between 92 to 105 volts and reducing input between 134 and 150 volts. Output voltage in battery mode is regulated to 120 volts +/- 5%. Line interactive system corrects voltage to nominal levels, boosting input between 92 to 105 volts and reducing input between 134 and 150 volts. Output voltage in battery mode is regulated to 120 volts +/- 5%. Line interactive system corrects voltage to nominal levels, boosting input between 92 to 105 volts and reducing input between 134 and 150 volts. Output voltage in battery mode is regulated to 120 volts +/- 5%.
Full Load Runtime (min.) 5 5 5 9 7 8
1/2 Load Runtime (min.) 17 17 17 26 23 24
Typical Runtime (min.) up to 32 min. up to 38 min. up to 52 min. up to 58 min. up to 68 min. up to 78 min.
Recharge Rate (hours) 2-4 2-4 2-4 2-4 2-4 2-4
Transfer time (ms.) 2-4 2-4 2-4 2-4 2-4 2-4
Joules 360 360 360 480 480 480
Maximum Surge Current (amps) 27,000 27,000 27,000 36,000 36,000 36,000
Suppression Response Time Less than one nanosecond Less than one nanosecond Less than one nanosecond 0 ns. (instantaneous) 0 ns. (instantaneous) 0 ns. (instantaneous)
EMI/RFI Noise Reduction Greater than 40 dB @ 1 MHz Greater than 40 dB @ 1 MHz Greater than 40 dB @ 1 MHz Greater than 80 dB @ 1 MHz Greater than 80 dB @ 1 MHz Greater than 80 dB @ 1 MHz
High Volt Switch to Battery 150 150 150 150 150 150
Low Volt Switch to Battery 92 92 92 92 92 92
Outlet Type (f) 3 NEMA 5-15R 6 NEMA 5-15R
(3 UPS/3 Surge)
6 NEMA 5-15R
(3 UPS/3 Surge)
6 NEMA 5-15R 6 NEMA 5-15R 6 NEMA 5-15R
Cord Length 6 ft. 6 ft. 6 ft. 6 ft. 6 ft. 6 ft.
Plug Type (m) NEMA 5-15P NEMA 5-15P NEMA 5-15P NEMA 5-15P NEMA 5-15P NEMA 5-15P
Dimensions HxWxD (inches) 8.25 x 4.75 x 7 8.25 x 4.75 x 7 10.5 x 4.75 x 7 12.75 x 6.5 x 8.75 12.75 x 6.5 x 8.75 10 x 6.5 x 14
Shipping Weight (lb.) 13 15.5 20.5 28 37 44
Fax/Modem Surge Protection Set of RJ11 jacks protects a single phone line. Set of RJ11 jacks protects a single phone line. Set of RJ11 jacks protects two phone lines. Not included. Order add-on module #DTEL2 Not included. Order add-on module #DTEL2 Not included. Order add-on module #DTEL2
Network Interface Port Built in DB9 SMART communications port for use with bundled PowerAlert software and cabling. Built in DB9 SMART communications port for use with bundled PowerAlert software and cabling. Built in DB9 SMART communications port for use with bundled PowerAlert software and cabling. Built in DB9 SMART communications port for use with bundled PowerAlert software and cabling. Built in DB9 SMART communications port for use with bundled PowerAlert software and cabling. Built in DB9 SMART communications port for use with bundled PowerAlert software and cabling.
Software and Cable Included Includes cable and PowerAlert Software Includes cable and PowerAlert Software Includes cable and PowerAlert Software Includes cable and PowerAlert Software Includes cable and PowerAlert Software Includes cable and PowerAlert Software
Product Warranty (yr.) 2 2 2 2 2 2
Ultimate Lifetime Insurance $50,000 $50,000 $50,000 $50,000 $50,000 $50,000
Battery Access Battery Access Door Battery Access Door Battery Access Door Battery Access Door Battery Access Door Battery Access Door
Controls, Indicators, and Additional Features On/off and Self test/alarm silence switches, LEDs indicate on-line, on-battery, voltage correction, and battery low/replace. Audible alarms. On/off and Self test/alarm silence switches, LEDs indicate on-line, on-battery, voltage correction, and battery low/replace. Audible alarms. On/off and Self test/alarm silence switches, LEDs indicate on-line, on-battery, voltage correction, and battery low/replace. Audible alarms. On/off and Self test/alarm silence switches, LEDs indicate on-line, on-battery, voltage correction, and battery low/replace, load level. Audible alarms. On/off and Self test/alarm silence switches, LEDs indicate on-line, on-battery, voltage correction, and battery low/replace, load level. Audible alarms. On/off and Self test/alarm silence switches, LEDs indicate on-line, on-battery, voltage correction, and battery low/replace, load level. Audible alarms.

Back To Top
2004 Sentinel Power Inc. All rights reserved.
Last Updated 03/18/10