Product Description:

ACI temperature transmitters are a cost effective solution for all temperature measurement. The transmitters are accurate, durable, and reliable. Numerous configurations for measurement in many different mediums are offered.

ACI produces two temperature transmitters, the ACI/TT100 for use with a 100 ohm RTD input and the ACI/TT1000 for use with a 1000 ohm RTD input. The transmitters produce a linear 4-20 mA output carried on a two-wire system. Optional voltage ranges of (1-5 or 2-10 VDC) can also be ordered. The power input to the transmitter can vary from 7 to 35 VDC, can be unregulated, and is not polarity sensitive. The transmitter is supplied factory calibrated, but also has zero and span potentiometers for field adjustments or calibration. The transmitter is linear from -50 to 392oF. The current output is unsusceptible to EMI and measurement resistances less than 800 Ohms. Additional options include current limiting and an AC input.

The ACI transmitter is available in numerous configurations to satisfy all the industry standards. The room transmitter is encased in an unobtrusive plastic enclosure and can be equipped with setpoint and override combinations. The transmitter can be ordered on a surface plate made of either stainless steel or aluminum. For air duct measurements, TT's are offered with 4, 8, 12, and 18" probes, as a remote probe with a 6 foot lead wire, or as strap-on. There are averaging configurations in 12' and 24' lengths. Lastly, the TT's can come as immersion with 4 or 8" high quality stainless steel thermowells. All duct and outside air configurations are available inside a weatherproof enclosure.

Product Specifications:
Input 2 wire Platinum 100/1000 Ohm RTD Transmitter Accuracy +/- 0.1% of Span
Output 2 wire, Linear 4 to 20mA DC current Sensor Accuracy0.12% @ 32F
Supply Voltage 7 to 35 VDC No Polarity Sensitivity Temperature Sensor Range -58 to 392F
Linearity +/- 0.05% of span Transmitter Operating Range 32 to 158F

RoomOutside Stainless Plate
Duct/ImmersionAveraging-12', 24'
Strap OnBullet Probe
Duct without Box


Ordering Information:
Span ConfigurationOutput
ACI/ -[]-[] -[]-[]
TT100 (1) 40 TO 90F R-Room(1) 1 to 5VDC
TT1000 (2) 30 TO 100F RS-Room w/Setpoint(2) 2 to 10VDC
(3) 20 TO 120F RO-Room w/Override(4) 4 to 20mA
(4) 40 TO 140F RSO-Room w/Setpoint & Override
(5) 40 TO 240F RSO-4-20 Slide-Room w/Override and 4-20mA Setpoint 
(6) -30 TO 130F D-Duct-4", 8", 12",18" 
(7) 0 TO 150FDO-Duct without Box-4", 8", 12", 18"
(8) Specify I-Immersion 4", 8" 
A-Averaging 12', 24'
S-Strap On
O-Outside Air
SP-Stainless Plate
RP-Remote Probe (1" x 1/4" cup 6' leads)